A certificate for candidates means a lot. It not only means that your efforts are valid, but also means that your ability has been improved. D-PEXE-IN-A-00 exam bootcamp will make your efforts receive rewards. Our D-PEXE-IN-A-00 exam dumps contain the most of knowledge points, they will help you to have a good command of the knowledge as well as improve your ability in the process of learning the D-PEXE-IN-A-00 Exam Bootcamp. In addition, we are pass guaranteed and money back guaranteed if you fail to pass the exam dumps, so you don’t need to worry that you will waste your money.

EMC D-PEXE-IN-A-00 Exam Syllabus Topics:

TopicDetails
Topic 1
  • Putting the server into the rack: This section of the exam includes securely mounting the server in a compatible rack, ensuring proper airflow and cable management.
Topic 2
  • Unpacking the server: This section of the exam covers safely removing the server from its packaging, inspecting for damage, and identifying all included components.
Topic 3
  • Connecting power and network cables: This domain covers connecting the server to a power source with the appropriate cable and voltage, and connecting it to the network using compatible cables.
Topic 4
  • Pre-installation tasks: This section involves preparing the environment and server for installation, including reviewing documentation, gathering tools, and verifying the proper workspace.

>> Exam D-PEXE-IN-A-00 Syllabus <<

Valid D-PEXE-IN-A-00 Test Sims | D-PEXE-IN-A-00 Exam Fees

The EMC D-PEXE-IN-A-00 exam questions pdf is properly formatted to give candidates the asthenic and unformatted information they need to succeed in the D-PEXE-IN-A-00 exam. In addition to the comprehensive material, a few basic and important questions are highlighted and discussed in the D-PEXE-IN-A-00 Exam Material file. These questions are repeatedly seen in past Dell PowerEdge XE9680 and XE8640 Install exam papers. The Dell PowerEdge XE9680 and XE8640 Install practice questions are easy to access and can be downloaded anytime on your mobile, laptop, or MacBook.

EMC Dell PowerEdge XE9680 and XE8640 Install Sample Questions (Q10-Q15):

NEW QUESTION # 10
A deployment engineer is installing a PowerEdge XE8640 server. The rack has four PDUs. Looking at the rear of the rack, one power source provides power to the two left PDUs. A different power source provides power to the two right PDUs.
What side of the rack should XE8640 PSU 1 and PSU 2 be connected?

  • A. PSU 2 in the left and PSU 1 in the right
  • B. PSU 1 in the left and PSU 2 in the right
  • C. PSU 1 and PSU 2 in the left PDUs
  • D. PSU 1 and PSU 2 in the right PDUs

Answer: B

Explanation:
* Redundancy and Load Balancing:
* PowerEdge XE8640 servers are designed for high availability and reliability. One key aspect of this design is the redundancy provided by the server's Power Supply Units (PSUs). By connecting
* each PSU to a different power source, you ensure that the server remains operational even if one power source fails.
* Power Source Configuration:
* In this scenario, the rack has two distinct power sources: one supplying power to the two left PDUs and the other to the two right PDUs. To maximize redundancy, each PSU should be connected to a different power source.
* PSU Placement:
* PSU 1 in the left PDUs: Connect PSU 1 to one of the PDUs on the left side of the rack. This ensures that PSU 1 is powered by the first power source.
* PSU 2 in the right PDUs: Connect PSU 2 to one of the PDUs on the right side of the rack. This ensures that PSU 2 is powered by the second power source.
* Ensuring Redundancy:
* By placing PSU 1 on the left and PSU 2 on the right, you create a redundant power configuration.
If either power source fails, the other PSU can continue to supply power to the server, maintaining its operation.
* Steps for Connection:
* Step 1: Verify that the rack's PDUs are correctly connected to their respective power sources.
* Step 2: Identify the left and right PDUs based on their power source connections.
* Step 3: Connect PSU 1 to a PDU on the left side of the rack.
* Step 4: Connect PSU 2 to a PDU on the right side of the rack.
* Step 5: Confirm that both PSUs are securely connected and receiving power from separate sources.
* Safety and Verification:
* Ensure that all connections are secure and that the cables are managed to prevent interference with other components or airflow within the rack. Verify that each PSU is functioning correctly by checking the server's power status indicators.
References:
* Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on PSU connections and power redundancy configurations.
* Dell EMC Technical Specifications Guide: Offers comprehensive details on the power requirements and redundancy features of the PowerEdge XE8640.


NEW QUESTION # 11
A deployment engineer is installing a PowerEdge XE8640 server. The server is on a lift, and they have aligned the server inner rails with the rail assemble that are secured in the rack. The engineer can only push the server into the rack a short distance before it stops. Pushing forcefully causes the rack to slide back.
What action should the deployment engineer take?

  • A. Lower the lift and move away from the server.
  • B. Press the mechanism on the rail to release the rail lock.
  • C. Pull the server out of the rack and realign the lift with the rack.
  • D. Have a person hold the rack while using force to slide in the server.

Answer: B

Explanation:
* Understanding Rail Locks:
* The PowerEdge XE8640 server rails are equipped with a locking mechanism to secure the server during transport and installation. This prevents the server from moving unintentionally and ensures stability.
* Identifying the Issue:
* When the server stops after being pushed only a short distance into the rack, it is likely due to the rail lock engaging. This lock must be released to allow the server to slide fully into place.
* Releasing the Rail Lock:
* Locate the rail lock mechanism on the rails. This is typically a lever or button that, when pressed, releases the lock, allowing the server to slide further into the rack.
* Detailed Steps:
* Align the Server: Ensure that the server is properly aligned with the rails before proceeding.
Misalignment can cause the server to get stuck or make it difficult to release the lock.
* Press the Release Mechanism: With the server partially inserted, locate and press the release mechanism on both sides of the rails. This should disengage the locks.
* Slide the Server: Once the locks are released, carefully push the server into the rack until it is fully seated. Ensure that the server is evenly aligned to avoid binding or getting stuck.
* Avoiding Forceful Methods:
* Avoid using excessive force to push the server into the rack as it can cause damage to the server, rails, or rack. Additionally, pushing forcefully without releasing the rail lock can lead to misalignment and potential hardware issues.
* Safety and Assistance:
* Ensure the lift is stable and properly aligned with the rack to prevent movement. If needed, have an assistant stabilize the lift while performing the installation steps.
* Reference to Official Documentation:
* Refer to the Dell EMC PowerEdge XE8640 Installation and Service Manual for specific instructions and diagrams illustrating the rail lock mechanism and proper installation procedures.
References:
* Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on the proper use of rail kits and the mechanism for releasing rail locks during server installation.
* Dell EMC Technical Specifications Guide: Offers comprehensive details on the hardware specifications and installation processes for Dell PowerEdge servers, including rail systems and locking mechanisms.


NEW QUESTION # 12
A deployment engineer is installing eight PowerEdge XE9680 servers. Two servers will be installed in each of four racks. The data center managers must plan for the power needed to supply power to the four racks.
What power consumption information can the deployment engineer give the data center manager?

  • A. Each PDU must use a C20-type connection.
  • B. Each rack must power 12, 2800-Watt, 15.6 Amp PSUs.
  • C. Each rack must have at least 6 PDUs for power high availability.
  • D. Each server has four 2800-Watt, 15.6 Amp PSUs.

Answer: D

Explanation:
The PowerEdge XE9680 server is equipped with power supply units (PSUs) that are essential for its operation.
Here's the power consumption information that the deployment engineer can provide:
* PSU Specifications: Each PowerEdge XE9680 server comes with four 2800-Watt, 15.6 Amp PSUs1.
This specification is crucial for the data center manager to understand the power requirements for each server.
* Total Power Requirement: With two servers per rack, each rack will have a total of eight 2800-Watt PSUs. This information helps in calculating the total power draw for each rack.
* Power Distribution Units (PDUs): While the number of PDUs required for high availability can vary, it's important to note that the server's PSUs feature a C22 input socket1. The data center manager should ensure that the PDUs in the rack are compatible with this type of connection.
* Power Planning: The data center manager must plan for the power needed to supply power to the four racks, considering the power draw of the servers and any additional equipment that will be installed.
By providing this detailed power consumption information, the deployment engineer assists the data center manager in planning for the appropriate power infrastructure to support the PowerEdge XE9680 servers.


NEW QUESTION # 13
A deployment engineer is connecting the network cables on an XE9680 server. The data center administrator wants to know why the server does not have an OCP card for network connectivity.
How should the engineer respond to the administrator's query?

  • A. The server does not support an OCP card.
  • B. An OCP card is required for the server to achieve POST when powered on.
  • C. The LOM card acts as an OCP card and supports OCP 3.0.
  • D. The OCP card is an optional component.

Answer: D

Explanation:
* Overview of OCP Cards:
* Open Compute Project (OCP) cards are network interface cards designed to provide high-speed networking capabilities. They are often used in data center environments to enhance network performance and flexibility.
* OCP Card on Dell PowerEdge XE9680:
* For the Dell PowerEdge XE9680 server, an OCP card is not a mandatory component. The server can achieve Power-On Self-Test (POST) and function normally without an OCP card.
* Optional Component:
* The OCP card is considered an optional component for the XE9680 server. This means it can be added based on specific networking needs but is not essential for the server's basic operations.
* Networking Alternatives:
* The XE9680 server is equipped with various other network interface options. For instance, it has integrated network ports (LAN on Motherboard, or LOM) which provide necessary network connectivity out-of-the-box.
* Customization and Upgrades:
* The optional nature of the OCP card allows data center administrators to customize their servers based on their network performance requirements. If high-speed or specific networking features are needed, the OCP card can be added accordingly.
* Communicating with the Administrator:
* The deployment engineer should explain to the data center administrator that while the OCP card is not included by default, it can be added as per the data center's specific networking needs. The server's design supports flexibility in network configurations.
References:
* Dell EMC PowerEdge XE9680 Installation and Service Manual: This manual provides detailed information on the components and optional upgrades available for the XE9680 server.
* Dell EMC Networking Guide: This guide outlines various networking options and configurations available for Dell PowerEdge servers, including the role and installation of OCP cards.


NEW QUESTION # 14
A deployment engineer installed and powered on a XE8640 server. The Linux operating system is installed.
They need to update the drivers on the server.
What is a consideration before updating the driver?

  • A. The driver package only supports Windows operating systems.
  • B. A single graphics driver supports all modern GPUs.
  • C. You can upload the driver package using the iDRAC UI.
  • D. Each GPU model has a distinct driver package.

Answer: D

Explanation:
* Understanding GPU Drivers:
* Graphics Processing Units (GPUs) require specific drivers to ensure optimal performance and compatibility with the operating system. Each GPU model typically has a unique driver package designed to leverage its capabilities and architecture.
* Driver Packages for Different GPU Models:
* For the Dell PowerEdge XE8640, which may be equipped with multiple GPU models, it is crucial to identify the exact GPU models installed in the server. Each GPU model, whether it's from NVIDIA, AMD, or another manufacturer, will have a distinct driver package.
* Importance of Model-Specific Drivers:
* Using the correct driver for each GPU model ensures that the GPU operates efficiently, provides the intended performance, and remains stable under various workloads. Incorrect drivers can lead to suboptimal performance, compatibility issues, or system instability.
* Steps to Update Drivers on Linux:
* Identify the GPU models installed in the server. This can be done using commands likelspci | grep
-i vgaor similar tools that list the hardware components.
* Visit the GPU manufacturer's website (e.g., NVIDIA, AMD) to download the appropriate drivers for each GPU model.
* Follow the manufacturer's installation instructions, which typically involve downloading the driver package, extracting it, and running an installation script or using package management tools.
* Using iDRAC for Driver Updates:
* While the iDRAC (Integrated Dell Remote Access Controller) UI can be used for various management tasks, uploading driver packages directly via iDRAC is not typically supported.
Drivers are usually installed within the operating system environment.
* Compatibility with Linux:
* Ensure that the driver package is compatible with the Linux distribution and kernel version installed on the XE8640. GPU manufacturers often provide detailed compatibility information and installation guides specific to various Linux distributions.
* Reference to Official Documentation:
* Dell's support site and the GPU manufacturer's documentation provide comprehensive guides on downloading and installing the correct drivers for various operating systems, including Linux.
References:
* Dell EMC PowerEdge XE8640 Installation and Service Manual: This manual provides detailed guidelines on hardware configurations and driver installations.
* NVIDIA/AMD Official Documentation: These resources offer specific instructions on downloading and installing GPU drivers for different operating systems and GPU models.


NEW QUESTION # 15
......

Do you want to find a high efficiency way to prepare for D-PEXE-IN-A-00 exam test?As we all know, high efficiency will produce unbelievable benefits. With our EMC D-PEXE-IN-A-00 study pdf, you can make full use of your spare time. If you are tired of screen reading, you can print D-PEXE-IN-A-00 Pdf Dumps into papers. You take your spare time to prepare and study. You will get your D-PEXE-IN-A-00 exam certification with less time investment. Come on, everyone, Choose D-PEXE-IN-A-00 test dumps, you will succeed.